





Product description


ADJUSTABLE TIME DELAY & SENSITIVITY
The time delay is adjustable from 15 seconds up to 30 minutes and provides a coverage range of up to 30 feet.
D1 Ceiling Occupancy Motion Sensor – High Bay Fixture Mount 360 Degree
PASSIVE INFRARED TECHNOLOGY
This high bay occupancy sensor uses passive infrared (PIR) technology to detect movement in the surrounding space, and automatically turn the lights on and off based on motion in the area. It is a compact, white motion sensor that blends right into your ceiling.
SAVE TIME & ENERGY
Protects & extends lamp life while maximizing energy savings by turning the lights off when it detects no movements in a given duration of time.

IDEAL FOR HIGH CEILINGS
This occupancy sensor is designed to replace a standard light or fan switch. It is ideal for high mounted areas such as warehouses, manufacturing, and other high ceiling applications.
Add to Cart
Customer Reviews
4.2 out of 5 stars 708
4.0 out of 5 stars 637
4.1 out of 5 stars 501
4.0 out of 5 stars 269
—
4.5 out of 5 stars 467
Price
— no data
— no data
$22.35$22.35
— no data
— no data
— no data
Sensor Technology
Passive Infrared (PIR) Passive Infrared (PIR) Passive Infrared (PIR) no data
no data
no data
Modes
Auto ON/Auto OFF, Manual ON/Auto OFF Auto ON/Auto OFF, Manual ON/Auto OFF Auto ON/Auto OFF no data
no data
no data
Load Types
LED, Incandescent, Fluorescent, CFL LED, Incandescent, Fluorescent, CFL LED, Incandescent, Fluorescent, CFL no data
no data
no data
Time Delay
5 sec (Test), 5 min, 10 min, 20 min, 30 min 5 sec (Test), 5 min, 10 min, 20 min, 30 min 15 sec – 30 min no data
no data
no data
Voltage
120-277VAC 120-277VAC 120-277VAC no data
no data
no data
Multi-Way Capability
no data
✓
no data
no data
no data
no data
Neutral Wire Required
Required Required no data
no data
no data
no data
Wall Plate Included
✓
✓
✓
✓
✓
✓
UL Listed
✓
✓
✓
✓
✓
✓
CA Title 24 Compliant
✓
✓
✓
no data
no data
no data
An ideal 360 degree high bay occupancy sensor for high mounted areas like warehouses, manufacturing and other commercial spaces designed to replace standard light or fan switches
Featuring latest motion sensor technology, this UL listed ceiling occupancy sensor offers practices in energy-saving, extending lamp life and maximizing time with adjustable controls, time delay and light level
Extend lamp life and maximize time and energy savings by programming lights to turn off when no motion is detected in occupancy vacancy motion sensor 360 degree. Taking care of energy saving practices, and convenience with occupancy and vacancy motion sensors
Equipped with Passive Infrared Technology PIR, this high-quality motion sensor detects heat-emitting sources, automatically turning lights on and off according to the movement in the area. 120v great for businesses, commercial and industrial properties
Adjustable time delay from 15 seconds to 30 minutes and a sensitivity coverage up to 30 feet, this motion sensor light provides an innovative, smart adaptive technology for a larger coverage, perfect for businesses, commercial and industrial properties
8 reviews for Ceiling Occupancy Motion Sensor, Passive Infrared Technology, High Bay Fixture Mount 360 Degree, Hard-Wired, 120-277 VAC, Commercial/Industrial Grade, 10-Pack
Add a review
$18.99

Bob –
Good motion sensor
In summary: Good product, pretty good instructions, and very good price. I attached this to a small metal Junction box with 1/2 inch knock-outs, and mounted it to the ceiling of my garage. Then added the plug end of a heavy duty extension cord to bring power to the box, and installed a duplex outlet for plugging in two shop lights. The outlets turn on whenever there is motion below, and stay on for 5 minutes (the minimum setting) after I leave. When working at by bench, with my back to the sensor, it usually picks up my arm motion and stays on for as long as I am in the area. Only once in three months has it turned off while I was working, and that was resolved by simply turning around – which triggered the lights back on. My device triggers on most any motion that lies within a 45 degree cone from the ceiling. Note that Time knob only has a few different values. It is Not infinitely adjustable. However my unit was settable down to 5 minutes, which is perfect for my use. Note also that the Instructions do not say how to adjust the “Light”knob. If you know exactly what it does, put it in a review so future customers will know.
Val Metrik –
works as described
works really great!
Jack Carious –
Good working detector with incorrect wiring diagram
I bought this unit to replace the pull on/off switch. Looking at the wires of the units, I was just gonna match wiring. I thought I should check the instruction just in case. Everything seems normal, and there was a wiring diagram. It seems odd the way it was drawn. It shows the black wires (from power, detector, and to light) connected together on one side, and the white wires (from power, detector, and to light) connected together. Because the detector has a red wire (3rd wire), it’s connected to the white wire that leads to the light. So, I joined the red wire with the white wires in one twist cap. Then I plug the cord to the outlet, and there was noise as if the light bulb burned. I removed the detector unit, plugged in the light, and no light. I searched the problem with no success. Then I realized it might’ve been the breaker. I checked and it was tripped. So, following the diagram, I short-circuited the breaker switch.Went back to my original thinking of matching the wires and using the little knowledge of wiring, I wired the black wire from the power to the black wire of the detector, the RED WIRE OF THE DETECTOR TO THE BLACK WIRE OF THE LIGHT, and all the white wires in twist cap. Plugged in, and the light turned on. After some seconds passed, light turned off. I moved to the detection area, and light turned on. I wonder if the company ever test its own instruction and diagram.
Michael Nunan –
Connecting is a snap when reviewers mention correct wiring instructions.
I always like to read “other buyers reviews” and look over a PDF install instructions when provided. This really poor wiring instruction diagram stood out as confusing. Thanks for other buyer’s reviews thatmade it simple. Disconnect the the black wire from “power source” and wire direct to black wire from”sensor”. The ” red sensor wire” is then connected it to the other black wire just disconnected coming “out of light fixture”. Wiring the “white sensor wire to white neutral bundle or white wire’ coming from the power source receptacle to complete the wiring job. It should be mentioned not all 3 way switchtraveler wires coming into the power sources receptacle box are the same color so hopefully yourelectrician wired a “black pigtail” to hot source to eliminate confusion when the connecting a light or other device. I spent a few hours researching the best way to handle my wife’s requested for an auto on auto off light upgrade. In my case a wall switch motion sensor was out the question and this motion sensor sure made the project extremely simple. Fifteen minutes to install on my overhead florescence light. My motion sensor works just fine and I would recommend it to others.
DaveNLR –
Timer is not linear
The produce was installed in an overhead kitchen light with two 4′ LED tubes. It performs well, and the sensitivity worked great to ignore the cats while picking up the dogs and people.The big complaint is: It has an analog time dial, which SHOULD allow you to gradually increase the on time from the default 15 seconds on up to whatever you want. In reality, it goes from 15 seconds directly to 5 minutes with no middle ground. 15 seconds is ok *IF* you are moving around, but if you pause to fill a pitcher at the sink without waving your arms, the light shuts off. If you set it at 5 minutes, it tends to see a dog or something, and never shut off. I really needed it to stay on for 45 second to 1 minute.I am just leaving it at 15 seconds and waving a lot.
LED Zone –
BEST OCCUPANCY SENSOR
REALLY EASY TO INSTALL WORKS GREAT ON HIGHBAY LIGHTS ALSO WE HAVE BOUGHT OVER 100 OF THEM ALREADY ITS OUR TOP SELLER
c scheel –
Stop Working After Short Time – DO NOT PURCHASE
We are an electrical contractor and purchased 31 of these for a job. Over the last 3 months the client has called multiple times to report occ sensor failure. I have had to replace over half of these already with higher quality occ sensors. Customer now requires that I replace them all. Costly lesson. DO NOT BUY THESE. THEY ARE GARBAGE.
Carolyn –
Automatic Lighting
I will be using my EVERElectrix to automatically turn on my lights in my garage. I love that it will automatically turn my lights off again when I leave the garage.